Nortel Communication Server 1000
Communication Server 1000M
and Meridian 1 Large System
Overview
NN43021-110
.
Vista de pagina 0
1 2 3 4 5 6 ... 73 74

Indice de contenidos

Pagina 1 - Overview

Nortel Communication Server 1000Communication Server 1000Mand Meridian 1 Large SystemOverviewNN43021-110.

Pagina 2

10 Introduction•Communication Server 1000M Multi Group (CS 1000M MG) CP PII,CP PIV•Meridian 1 PBX 11C Chassis•Meridian 1 PBX 11C Cabinet•Meridian 1 PB

Pagina 3 - Revision history

Related information 11The following systems are referred to generically as "Large System":•Communication Server 1000M Single Group (CS 1000M

Pagina 4 - 4 Revision history

12 IntroductionNortel Communication Server 1000Communication Server 1000M and Meridian 1 Large System OverviewNN43021-110 01.03 StandardRelease 5.0 18

Pagina 5 - Contents

13Product descriptionContentsThis section contains information on the following topics:"Introduction" (page 13)"System options" (p

Pagina 6 - Index 71

14 Product descriptionAll Large Systems consist of Universal Equipment Modules (UEM) stackedone on top of another to form a column. Each column contai

Pagina 7 - How to get help

System options 15•CS 1000M MG, Meridian 1 PBX 81C CP PIV, Meridian 1 Option 81,and Meridian 1 Option 81C: enhanced common control complex, dualCPU, an

Pagina 8 - 8 How to get help

16 Product descriptionFigure 2CS 1000M HGTable 2Specifications for CS 1000M HG and Meridian 1 Option 51CSystem characteristics:Maximum number of ports•

Pagina 9 - Introduction

System options 17Succession 3.0•CP3 NT5D10 CP or CP4 NT5D03 cardCS 1000 Release 4.5•CP3 NT5D10 CP or CP4 NT5D03 cardSoftware generic•2811Base hardware

Pagina 10 - Conventions

18 Product description•System Monitor•PDUPedestal (one per column)•Blower unit•Thermostat harnessTop cap (one per column)•Air probe harnessCS 1000M SG

Pagina 11 - Related information

System options 19Figure 3Meridian 1 PBX 61C CP PIV or Meridian 1 Option 61CFigure 4CS 1000M SGTable 3 "Specifications for CS 1000M SG and Meridian

Pagina 12 - 12 Introduction

Document status: StandardDocument version: 01.03Document date: 18 February 2008Copyright © 2003-2008, Nortel NetworksAll Rights Reserved.Sourced in Ca

Pagina 13 - Product description

20 Product descriptionTable 3Specifications for CS 1000M SG and Meridian 1 PBX 61C CP PIVSystem characteristics:Maximum number of ports•2000Input volta

Pagina 14 - System options

System options 21•Network cards•Superloop Network cards•Conference/TDS card•CE power supply•Hybrid Bus TerminatorsCards in the back of the module:•Sys

Pagina 15 - System options 15

22 Product description•Thermostat harnessTop cap (one per column)•Air probe harnessCS 1000M MG and Meridian 1 PBX 81C CP PIVThe CS 1000M MG and Meridi

Pagina 16 - Release 5.0 18 Februar y 2008

System options 23Figure 6CS 1000M MGTable 4 "Specifications for CS 1000M MG and Meridian 1 Option 81C CPPIV" (page 23) lists specifications fo

Pagina 17

24 Product description•128 MB•256 MB•CP3 NT5D10, required for CS 1000 Release 4.5Memory•CP4 NT5D03, required for CS 1000 Release 4.5Base hardware:Card

Pagina 18

System options 25•Hybrid Bus TerminatorsCards in the back of the module:•System Utility Transition (Sys Util Trans) card•cCNI Transition (cCNI Trans)

Pagina 19 - 1 PBX 61C CP PIV

26 Product description•System monitor•Power Distribution Unit (PDU)Pedestal (one per column)•Blower unit•Thermostat harnessTop cap (one per column)•Ai

Pagina 20

System modules 27Each Core/Network module houses up to four NT8D04 Superloop NetworkCards for a total of 16 network loops. Superloop Network cards are

Pagina 21

28 Product descriptionThe CS 1000M MG and Meridian 1 PBX 81C CP PIV support a FiberNetwork Fabric network system with a FIJI card in slots 8 and 9 on

Pagina 22

System modules 29Figure 8NT5D21 Core/Network moduleNT8D35 Network moduleThis module provides the network switching functions in the Meridian 1Option 8

Pagina 23

3Revision historyFebruary 2008Standard 1.03. This document is up-issued to update the CS 1000M SGand Meridian 1 PBX 61C CP PIV core complex graphic.Ju

Pagina 24

30 Product descriptionFigure 9NT8D35 Network moduleThe Network module can be used as a PRI/DTI expansion module. Thenumber of PRI/DTI expansion module

Pagina 25

System modules 31Figure 10NT8D35 Network module configured for PRI/DTI expansionFiber Network FabricFiber Network Fabric extends and enhances the five-g

Pagina 26 - System modules

32 Product descriptionFigure 11Four group Fiber Network Fabric configurationNT8D37 Intelligent Peripheral Equipment moduleThe Intelligent Peripheral Eq

Pagina 27 - Network side

System modules 33Figure 12NT8D37 IPE moduleFiber Remote IPE moduleThis module provides fiber-optic links between the network functions in aLarge System

Pagina 28 - NT5D21 Core/Network module

34 Product descriptionNortel Communication Server 1000Communication Server 1000M and Meridian 1 Large System OverviewNN43021-110 01.03 StandardRelease

Pagina 29 - NT8D35 Network module

35System architectureContentsThis section contains information on the following topics:"Hardware architecture" (page 36)"Common control

Pagina 30 - Figure 9

36 System architectureHardware architectureCS 1000M and Meridian 1 systems are circuit-switched digital systemsthat provide voice and data transmissio

Pagina 31 - Fiber Network Fabric

Hardware architecture 37Figure 13Large System basic architectureCommon control complexThe processor is the common control complex of the system. It pr

Pagina 32 - Figure 11

38 System architecture•the disk drive unit that provides mass storage for operating programsand data•I/O interfaces that provide an information exchan

Pagina 33 - Carrier Remote IPE

Hardware architecture 39•one Core-to-Network Interface (cCNI) cards•one System Utility Transition (Sys Util Trans) card•four cCNI Transition (cCNI Tra

Pagina 34 - 34 Product description

4 Revision historyNortel Communication Server 1000Communication Server 1000M and Meridian 1 Large System OverviewNN43021-110 01.03 StandardRelease 5.0

Pagina 35 - System architecture

40 System architectureThe cCNI Transition cards connect the Core module cards to the 3PE cardsin the Network modules. Each Core module contains betwee

Pagina 36 - Hardware architecture

Hardware architecture 41The cCNI Transition cards provide the cable connections to the 3PETermination Panel at the back of the module. A cCNI Transiti

Pagina 37 - Common control complex

42 System architectureThe Dual Ring fiber-optic cable configuration provides completenon-blocking communication between the Network groups; this elimina

Pagina 38 - 38 System architecture

Hardware architecture 43Figure 15Superloop segments in the IPE moduleA superloop is made up of NT8D04 Superloop Network cards, NT8D01AC orNT8D01BC Con

Pagina 39 - Hardware architecture 39

44 System architectureAs an example of a superloop configuration, Figure 16 "Eight segments persuperloop" (page 44) shows eight segments per

Pagina 40 - Figure 14

Hardware architecture 45analog signal at a rate of twice the highest signal frequency, then convertsthe amplitude into a series of coded pulses. For t

Pagina 41 - Network organization

46 System architectureIntelligent Peripheral Equipment cardsNumber ofterminationsNT8D09 Analog Message Waiting Line card16Trunk cards:NT5K07 Universal

Pagina 42 - 42 System architecture

Hardware architecture 47Intelligent Peripheral Equipment remote locationIn a local operating environment, IPE can be housed up to 15.2 m (50 ft)from t

Pagina 43 - Figure 15

48 System architectureAttendant consolesMeridian 1 attendant consoles provide high-volume call processing.Indicators and a 4 x 40 liquid crystal displ

Pagina 44 - Eight segments per superloop

Hardware architecture 49AC powerAC-powered systems require no external power components and canplug directly into commercial AC (utility) power. AC-po

Pagina 45

5ContentsHow to get help 7Getting help from the Nortel Web site 7Getting help over the telephone from a Nortel Solutions Center 7Getting help from a s

Pagina 46

50 System architectureA variety of rectifiers and distribution equipment can be used to supplyexternal DC power. Existing customer equipment can be use

Pagina 47 - Digital telephones

Hardware architecture 51The legacy Nortel ISP1100 Signalling Server can still be used.CS 1000 Release 5.0 introduces three new servers that can host a

Pagina 48 - Power equipment

52 System architectureThe Nortel CP PM server has the following components:•Intel Pentium M processor (1.4 Ghz)•internal hard drive•hot-pluggable Comp

Pagina 49 - DC power

Hardware architecture 53•4 GB PC2-4200 ECC DDR2 SDRAM (2 GB configured•Two 10/100/1000BaseT Ethernet ports•One CD-R/DVD ROM drive•One serial port•Three

Pagina 50 - Signaling Server

54 System architectureThe SIP Redirect Server NRS is hosted either co-resident with SignalingServer applications, or in a stand-alone mode on a dedica

Pagina 51 - Hardware architecture 51

Hardware architecture 55SIP ProxyCommunication Server (CS) 1000 Release 5.0 adds a transaction statefulSIP Proxy to the IP Peer Network.A SIP Proxy ac

Pagina 52 - 52 System architecture

56 System architectureNRS ManagerNRS Manager is a web-based management application used to configure,provision, and maintain the NRS. Key usability imp

Pagina 53 - Network Routing Service

Software architecture 57Office dataOffice data describes the characteristics of the system in terms ofconfiguration and call-dependent information, such

Pagina 54 - 54 System architecture

58 System architectureSoftware programs provide the system interface for maintenance, servicechange, and traffic measurement. Each program is independe

Pagina 55 - Element Manager

Configuration options 59The data dump program is also used to install a new generic version orissue and capture protected data store information (such

Pagina 56 - Software architecture

6 ContentsPower equipment 48Signaling Server 50Software architecture 56Firmware 56Software 56Office data 57Resident programs 57Nonresident programs 57C

Pagina 57 - Nonresident programs

60 System architectureFigure 19Large System to Remote IPE siteFiber Remote Multi-IPE InterfaceThe Fiber Remote Multi-IPE Interface links a Large Syste

Pagina 58 - Equipment data dump

Configuration options 61•Multi-mode fiber supporting four superloops•Multi-mode fiber supporting two superloopsFigure 20Meridian 1 Large System to Remote

Pagina 59 - Configuration options

62 System architectureA floor-standing column or a wall-mounted cabinet Carrier Remote IPEis installed at the remote site and is connected to the Merid

Pagina 60 - Figure 19

Configuration options 63communications network. The Call Server at the main office provides thecall processing for the IP Phones in both the main office

Pagina 61

64 System architectureNortel Communication Server 1000Communication Server 1000M and Meridian 1 Large System OverviewNN43021-110 01.03 StandardRelease

Pagina 62 - Branch Office

65List of termsACAlternating CurrentanalogA process that models information in the form of a continuously varyingparameter such as current, voltage, o

Pagina 63 - Geographic Redundancy

66 List of termsCBTCore Bus TerminatorCECommon EquipmentCentral Office (CO)The site where a telephone company terminates customer lines and housesthe s

Pagina 64 - 64 System architecture

List of ter ms 67CP PIV®The successor to the Pentium II from Intel. Pentium IV refers to the PentiumIV CPU chip.CPUCentral Processing UnitDCDirect Cur

Pagina 65 - List of terms

68 List of termsloopA bidirectional path between network equipment and peripheral equipment.module power suppliesIndividual power units that generate

Pagina 66 - 66 List of terms

List of ter ms 69SDISerial Data Interface. A family of cards equipped with SDI ports provide theI/O interface for the CS 1000M Large System and Meridi

Pagina 67 - List of ter ms 67

7How to get helpThis chapter explains how to get help for Nortel products and services.Getting help from the Nortel Web siteThe best way to get techni

Pagina 68 - 68 List of terms

70 List of termsUPSUniversal Power SupplyVACVoltage Alternating CurrentVDCVoltage Direct CurrentNortel Communication Server 1000Communication Server 1

Pagina 69 - List of ter ms 69

71IndexSymbols/Numerics3PE Termination Panel 41AAC-power 15, 26, 49, 49air filters 14airflow exits 14Bbackup capabilities 48batteries 49blower units 14C

Pagina 70 - Voltage Direct Current

72 IndexHheat (thermal) sensor assemblies 14II/O (input/output) interfaces 14, 38Initialize program 57Intelligent Peripheral Equipment (IPE)Modules 14

Pagina 72 - 72 Index

Nortel Communication Server 1000Communication Server 1000M and Meridian 1 Large SystemOverviewCopyright © 2003-2008, Nortel NetworksAll Rights Reserve

Pagina 73

8 How to get helpGetting help through a Nortel distributor or resellerIf you purchased a service contract for your Nortel product from a distributoror