328 Connecting the telephones
Refer to "Preprogrammed data" (page 373) for default DN
assignments.
Now, you can activate the telephone, as described in "Activating
telephones" (page 336).
—End—
Connecting analog 500/2500-type telephones with a PFTU
Procedure 63
Connecting 500/2500-type telephones with a PFTU
Step Action
1
Locate the telephone terminations on the cross-connect terminal.
2
Connect one end of the cross-connect wire to the leads of the
telephone.
3
Locate the PFTU connections (unit PFT 1 through PFT 5) assigned
to this telephone at the cross-connect terminal.
Refer to Table 48 "Power Failure Transfer Unit connections" (page
335).
4
Connect the other end of the cross-connect wire to the pair assigned
to the telephone on the PFTU.
5
Connect a second cross-connect wire to the pair assigned to the line
card on the PFTU.
6
Locate the line card terminations on the cross-connect terminal.
For the Cabinet system, refer to:
•
Table 45 "Terminal number assignments: Main and Expansion
Cabinets 1 and 2" (page 332) for the main cabinet and Expansion
Cabinets 1 and 2
•
Table 46 "Terminal number assignments: Expansion Cabinets 3
and 4" (page 333) for Expansion Cabinets 3 and 4
For the Chassis system, refer to:
•
Table 47 "Terminal Number assignments: Chassis and chassis
expander" (page 334) for the chassis and chassis expander
7
Connect the other end of the cross-connect wire to the assigned
TN terminal block.