Pagina 1 - Nortel AS 5300 Installation

Application Server 5300Nortel AS 5300 InstallationRelease: 1.0Document Revision: 01.04www.nortel.comNN42040-300.

Pagina 2

10 IntroductionFor medium redundant systems, the minimum baseline configuration forthe AS 5300 infrastructure includes four (4) IBM x3550 servers with

Pagina 3 - Contents

100 Maintenance ReleasesQuerying the Network Interface Card firmwareUse this procedure to determine the current Network Interface Card (NIC)firmware ve

Pagina 4 - Maintenance Releases 85

Firmware upgrades 101Querying the ServeRaid firmwareUse this procedure to determine the current ServeRAID firmware version.Prerequisites•You must be as

Pagina 5 - Procedures

102 Maintenance ReleasesIf the versions do not match, upgrade the firmware.--End--Installing the firmware upgradesUse these procedures to install firmw

Pagina 6

Installing the firmware upgrades 103The IBM Flash Update Utility appears.5Select 1 to update the BIOS.6 Reply Y to move the current image to the backu

Pagina 7 - New in this release

104 Maintenance ReleasesIf the firmware is out of date, the system flashes the firmware.5When the upgrade completes, remove the CD from the CD-ROMdriv

Pagina 8 - 8 New in this release

Installing the firmware upgrades 1055When the server reboot begins, remove the CD from theCD-ROM drive.--End--Installing RSA-II card firmware upgradesU

Pagina 9 - Introduction

106 Maintenance ReleasesInstalling NIC firmware upgradesUse this procedure to install NIC firmware upgrades. This procedurerequires the reboot of the s

Pagina 10 - 10 Introduction

Installing the firmware upgrades 107Procedure StepsStep Action1Load the hard drive firmware upgrade CD into the CD-ROMdrive.2 Log on to the server as

Pagina 11 - Installation overview

108 Maintenance ReleasesProcedure StepsStep Action1Load the ServeRAID firmware upgrade CD into the CD-ROMdrive.2Log on to the server as the SSA role (

Pagina 12 - Installation times

Multimedia PC Client upgrade 109Multimedia PC Client upgradeThis section provides the procedures that you use to upgrade theMultimedia PC Client. Choo

Pagina 13

11.Installation overviewThis chapter describes the steps required to install AS 5300 servers andthe approximate time needed to complete each step.Inst

Pagina 14

110 Maintenance Releasescd /var/mcp/run/MCP_11.0/PROV1_0/wars/pca/pcclientcode8Unzip the file:unzip <PCCLient>.zip--End--Upgrading the Multimedi

Pagina 15 - Installation preparation

111.DowngradesMaintenance Release and patch upgrades of the AS 5300 databaseare backwards compatible. However, if data in the database becomescorrupte

Pagina 16 - (page 17)

112 DowngradesDowngrade system components navigation• "Downgrading the AudioCodes gateway" (page 113)• "Downgrading the Network Element

Pagina 17 - Installation Planning sheet

Downgrade system components 113Downgrading the AudioCodes gatewayUse this procedure to downgrade the AudioCodes gateway. The onlysupported method for

Pagina 18

114 Downgrades3Do one of the following:If this is a downgrade to a previous Maintenance Release, editthe installprops.txt file as follows:ne.load=<

Pagina 19

Downgrade system components 115Procedure StepsStep Action1Log on to the Primary Database server as the DBA role(ntdbadm).2Change directory:cd /var/mcp

Pagina 20

116 Downgrades14Log on to the secondary database server as the DBA role(ntdbadm).15Change directory:cd /var/mcp/run/MCP_11.0/<dbname>_1/bin/util

Pagina 21 - Hardware installation and

Downgrade a full system 117Downgrade a full system navigation• "Preparing for full system downgrades" (page 117)• "Downgrading a redund

Pagina 22

118 Downgrades2Stop all active Provisioning Managers and Personal AgentManagers.From the System Manager console navigation tree, navigate toNetwork El

Pagina 23 - Mount the hardware

Downgrade a full system 119Downgrading a non-redundant system navigation• "Downgrading a non-redundant system with a replicated database"(pa

Pagina 24 - Connect the hardware

12 Installation overviewInstallation overview navigation•"Installation times" (page 12)Installation timesThis section describes the approxim

Pagina 25 - Figure 2

120 Downgrades• IP Client Managers• Fault-Performance Managers2Downgrade the database.3Downgrade the AudioCodes Gateway.4 Downgrade the System Manager

Pagina 26 - • Terminal emulation is VT100

121.Common proceduresThe following sections describe common procedures used while installingand configuring the AS 5300 system.Navigation•"Reboot

Pagina 27 - • Maintenance network

122 Common proceduresApplication Server 5300Nortel AS 5300 InstallationNN42040-300 01.044 November 2008Copyright © 2007-2008 Nortel Networks.

Pagina 29 - Network Time Protocol

Application Server 5300Nortel AS 5300 InstallationCopyright © 2007-2008 Nortel NetworksAll Rights Reserved.Printed in CanadaRelease: 1.0Publication: N

Pagina 30 - Hardware configuration

Installation times 13Table 1Installation preparationInstallation step Approximate time required to completeUnpacking the hardware 10 minutesTable 2Har

Pagina 31 - Hardware configuration 31

14 Installation overviewTable 5AS 5300 software deployment (cont’d.)Installation step Approximate time required to completeDeploying the initial softw

Pagina 32

15.Installation preparationThis section describes the preparation of materials and hardware requiredfor installing the AS 5300 server.Navigation•"

Pagina 33

16 Installation preparationThis sheet is located in the chapter titled "Installation Planning sheet"(page 17).Application Server 5300Nortel

Pagina 34

17.Installation Planning sheetThis section contains the Installation Planning Sheet.Use the Installation Planning sheet to compile the information req

Pagina 35 - Configuring the RSA-II card

18 Installation Planning sheetService VLAN Machine LogicalAddress All 10.10.0.5Service VLAN Default Gateway All 10.10.0.1Service VLAN Network Mask All

Pagina 36 - Configuring the planar BIOS

Customer-specific information 19ntsecadm All QWEpoi43@!ntbackup All QWEpoi43@!ntdbadm All QWEpoi43@!IAO Single Account Information, if used (not requi

Pagina 37

Application Server 5300Release: 1.0Publication: NN42040-300Document release date: 4 November 2008Copyright © 2007-2008 Nortel NetworksAll Rights Reser

Pagina 38 - Configuring the ServeRAID BIOS

20 Installation Planning sheetApplication Server 5300Nortel AS 5300 InstallationNN42040-300 01.044 November 2008Copyright © 2007-2008 Nortel Networks.

Pagina 39

21.Hardware installation andconfigurationThis section describes the procedures for installing and configuring theAS 5300 server hardware.PrerequisitesF

Pagina 40

22 Hardware installation and configurationHardware installation and configuration navigation•"Hardware overview" (page 22)• "Mount the h

Pagina 41

Mount the hardware 23Table 6IBM x3550 hardware characteristics (cont’d.)Item DescriptionServer identification x3550, Model 7978 AC1CPU 2 x Quad-Core I

Pagina 42

24 Hardware installation and configuration3Securely install the rail kit and then slide the server into place.4Ensure the server is supported in the r

Pagina 43 - Hardware configuration 43

Connect the hardware 25Figure 1Front panel of the AS 5300 serverFigure 2Rear panel of the AS 5300 serverEthernet 1 and Ethernet 2 are the main Network

Pagina 44

26 Hardware installation and configurationport is attached to another computer, such as a Windows-based computer,a program such as HyperTerminal can b

Pagina 45

Networking overview 27Attach the two redundant AC (Alternating Current) power modules toredundant AC power sources, as required by industry standards.

Pagina 46

28 Hardware installation and configurationFigure 3Typical Dual-VLAN configurationThe server maintains the use of the kernel channel bonding module toi

Pagina 47 - • Audit Daemon configuration

Networking overview 29VLAN interfaces are named according to the following syntax:<hosting_interface>.<vlan_id>The AS 5300 server defines

Pagina 48

3.ContentsNew in this release 7Features 7Other changes 7Introduction 9Deployment options 9Installation overview 11Installation times 12Installation pr

Pagina 49

30 Hardware installation and configurationcan have their time source server configured to use the System Managers,as IPsec is already configured betwe

Pagina 50

Hardware configuration 31Hardware configuration navigation• "Resetting the planar BIOS and RSA-II card to factory defaults" (page32)• "R

Pagina 51

32 Hardware installation and configuration• "Configuring the planar BIOS" (page 36)• "Configuring the ServeRAID BIOS" (page 38)Res

Pagina 52 - Navigation

Hardware configuration 33with the correct memory configuration but not recognized by thesystem. If this happens, contact your next level of support be

Pagina 53

34 Hardware installation and configurationWARNINGThe resetting of the ServeRAID BIOS to factory defaultsincludes the destruction of all currently defi

Pagina 54

Hardware configuration 3511Press F6 to reset to factory defaults.12Select Yes to reset the defaults.13 Press Esc until you return to the IBM ServerRAI

Pagina 55

36 Hardware installation and configuration9Highlight OS USB Selection and use the left and right arrowkeys to select Linux OS.10 Select Save Values an

Pagina 56

Hardware configuration 37Procedure StepsStep Action1Reboot the server and press F1 to access the planar BIOSconfiguration utility.The following steps

Pagina 57

38 Hardware installation and configuration25Select Exit Setup and select Yes when prompted forconfirmation.--End--Configuring the ServeRAID BIOSUse thi

Pagina 58 - • ntossadm

Hardware configuration 39The Array Properties window appears.15 In the Array Type sub-window, select RAID 1(Mirror).This cursor moves to Array Label.1

Pagina 59

4Configuring accounts and passwords 51Configuring preconfigured accounts and passwords 52Configuring a system for individual accounts 53Reinstalling p

Pagina 60

40 Hardware installation and configurationApplication Server 5300Nortel AS 5300 InstallationNN42040-300 01.044 November 2008Copyright © 2007-2008 Nort

Pagina 61

41.Platform software installationThis section describes how to install the AS 5300 platform software.The platform software consists of the underlying

Pagina 62

42 Platform software installationApplication Server 5300Nortel AS 5300 InstallationNN42040-300 01.044 November 2008Copyright © 2007-2008 Nortel Networ

Pagina 63 - AS 5300 software deployment

Hardware configuration 43Platform software installation navigation•"Starting the Linux operating system installation" (page 44)• "Confi

Pagina 64 - Staging files

44 Platform software installationStarting the Linux operating system installationUse this procedure to initiate the Linux operating system installatio

Pagina 65 - Installation properties file

Configuring the networking, serial console redirection, and time zone settings 45If the hardware verification fails, an error message displays, theins

Pagina 66

46 Platform software installation2Enter the VLAN number associated with the Service network.This number must match the VLAN ID associated with theServ

Pagina 67

Configuring the NTP, Syslog, and Audit Daemon settings 47Disable the serial console redirection by selecting option 3 andproceed to step 12.OREnable s

Pagina 68

48 Platform software installationPrerequisites• You have completed the steps described in "Configuring thenetworking, serial console redirection,

Pagina 69

Configuring the Primary (EMS1) and Secondary (EMS2) clock source servers 49Select Y to enable system audit. Enabling the system audit mightimpact syst

Pagina 70

5Installing the firmware upgrades 102Installing BIOS firmware upgrades 102Installing Base Management Controller (BMC) firmware upgrades 103Installing

Pagina 71

50 Platform software installationIf you are configuring the Secondary (EMS2) server, enter themachine logical address of the Primary (EMS1) server.--E

Pagina 72

Configuring accounts and passwords 51The closer that the starting system time from the BIOS is to the actual timereference provided by these clock sou

Pagina 73

52 Platform software installationThe installer presents the option to configure preconfigured accounts or anindividual account. You must select one or

Pagina 74 - 74 Patches

Configuring accounts and passwords 53Reply Y to accept the account method confirmation.ORReply N to go back to the User Accounts screen and changesele

Pagina 75

54 Platform software installationConfiguring a system for individual accountsProcedure StepsStep Action1 During the Linux operating system installatio

Pagina 76

Reinstalling platform software 55Configuring accounts and passwords job aidTable 8List of pre-configured accountsAccount name Descriptionntappadm This

Pagina 77

56 Platform software installationPrerequisites• You have completed the steps in "Starting the Linux operating systeminstallation" (page 44)

Pagina 78

Reinstalling platform software 57MCP Backup Tar Files1) mcpPlatform.as5300-micro-s1.yyyy.mm.dd.hh.mm.tar2) mcpPlatform.as5300-micro-s2.yyyy.mm.dd.hh.m

Pagina 79 - Patching the Network Elements

58 Platform software installationThe Date and Time is displayed.13Do one of the following:Enter Y to accept the configuration.OREnter N to change the

Pagina 80

59.Oracle database software installationThis chapter contains information and procedures for installing the Oracledatabase software. Oracle is install

Pagina 81

6Application Server 5300Nortel AS 5300 InstallationNN42040-300 01.044 November 2008Copyright © 2007-2008 Nortel Networks.

Pagina 82 - 82 Patches

60 Oracle database software installationNavigation• "Installing Oracle database software" (page 60)• For more information about installing O

Pagina 83

Oracle database software installation 61Procedure StepsStep Action1Place the first disc containing the Oracle installation files in theCD-ROM drive of

Pagina 84 - 84 Patches

62 Oracle database software installationOtherwise, you have completed installation.--End--Application Server 5300Nortel AS 5300 InstallationNN42040-30

Pagina 85 - Maintenance Releases

63.AS 5300 software deploymentThis chapter contains information and procedures about AS 5300 softwaredeployment.Navigation•"Core components"

Pagina 86 - 86 Maintenance Releases

64 AS 5300 software deploymentStaging filesStaging files are used to configure the initial system. The AS 5300software load includes two sets of stagin

Pagina 87

Core components 654-server staging files (medium system)4-server staging configurations consist of a redundant installation where allcore components a

Pagina 88

66 AS 5300 software deploymentAttention: For increased security, do not store the parameters fordb.username and db.password in the installprops.txt fi

Pagina 89

AS 5300 initial software deployment 67AS 5300 initial software deployment navigation• "Downloading the MCP load software" (page 68)• "P

Pagina 90

68 AS 5300 software deployment• "Starting the System Management Console" (page 71)• "Updating the licensekey" (page 71)Downloading

Pagina 91

AS 5300 initial software deployment 69The system displays a list of loads and prompts for a loadselection.3 Select the load for installation.The syste

Pagina 92

7.New in this releaseThe following sections detail what’s new in NN42040-300 Installation forNortel Application Server (AS) 5300 Release 1.0.FeaturesT

Pagina 93

70 AS 5300 software deploymentDeploying the initial software loadUse this procedure to deploy the initial AS 5300 software load.Prerequisites•You must

Pagina 94

AS 5300 initial software deployment 71For more information, see Nortel AS 5300 Planning and Engineering(NN42040-200).Starting the System Management Co

Pagina 95

72 AS 5300 software deployment7If you do not see the new licensekey after applying, clickRefresh.After the licensekey is updated, you can deploy and s

Pagina 96

73.PatchesThis section contains procedures for updating and maintaining the AS5300 system through the installation of software patches and firmwareupd

Pagina 97

74 PatchesMCP core software load patch installation navigation• "Obtaining the patches" (page 74)• "Patching the database schemas and S

Pagina 98 - Firmware upgrades

MCP core software load patch installation 75Always download the most recent patch. Patches arecumulative, that is, each new patch contains all of the

Pagina 99 - 3 Click Vital Product Data

76 PatchesUnix Path Location/patches/MCP/MCP_11.0.0.1_2008-01-05-2156.patch4Using an FTP client, download the patch from thegsds.ca.nortel.com site.Th

Pagina 100 - 4 November 2008

MCP core software load patch installation 77When you enable the RPS, an inform file is created in thevar/mcp/dropbox directory. When a patch has been

Pagina 101 - 2 Run the following command:

78 PatchesEnabling patch delivery for non-Regional Patch Selector (RPS) sitesUse this procedure to create an inform file for RPS patch notifications.

Pagina 102 - Procedure Steps

MCP core software load patch installation 79Procedure StepsStep Action1Log on to the primary System Manager as the AA role(ntappadm) using SSH.2Change

Pagina 103

8 New in this releaseApplication Server 5300Nortel AS 5300 InstallationNN42040-300 01.044 November 2008Copyright © 2007-2008 Nortel Networks.

Pagina 104

80 PatchesNetwork ElementClient impact Subscriber impactis transferred to the AccountingManager and no information islost.ProvisioningManagersThe Prov

Pagina 105

MCP core software load patch installation 81Prerequisites• Network Elements are configured on the system.•You understand the service issues associated

Pagina 106

82 Patches6 Repeat steps 3 to 5 for each Network Element displayed in thePatch/MR navigation tree.The Instance window for the Network Element shows on

Pagina 107

MCP core software load patch installation 83Prerequisites• The database schemas and System Manager have been patched.Procedure StepsStep Action1 The p

Pagina 108

84 PatchesApplication Server 5300Nortel AS 5300 InstallationNN42040-300 01.044 November 2008Copyright © 2007-2008 Nortel Networks.

Pagina 109 - Upgrading the ASU load

85.Maintenance ReleasesThis section describes information and procedures about installingMaintenance Releases. Use Maintenance Releases to update the

Pagina 110

86 Maintenance ReleasesMCP core software load Maintenance Release installation Navigation• "Transferring the Maintenance Release files to System

Pagina 111 - Downgrades

MCP core software load Maintenance Release installation 87• "Upgrading the Network Elements" (page 90)• "Upgrading the AudioCodes gatew

Pagina 112 - 112 Downgrades

88 Maintenance Releasesrm –Rf <old_load_directory>Attention: Use extreme caution when using rm -Rf commands.Entering a typo can cause an entire

Pagina 113

MCP core software load Maintenance Release installation 89sudo ./mcpCopyFromESD.pl -m manifest-online8Copy the ASU files.sudo ./mcpCopyFromESD.pl -m m

Pagina 114 - Downgrading a database

9.IntroductionThis document provides information about the installation of the IBMx3550 servers for Nortel Application Server (AS) 5300. It describes

Pagina 115

90 Maintenance Releases./mcpUpgradeMR.pl4When prompted, select the MR load from the list.The database is upgraded first, followed by the System Manage

Pagina 116 - Downgrade a full system

MCP core software load Maintenance Release installation 914Select the Network Element to be patched.5 On the maintenance panel, click the Upgrade butt

Pagina 117

92 Maintenance ReleasesThe load name listed for each instance is the patched load.--End--Upgrading the AudioCodes gatewayUse this procedure to apply t

Pagina 118

Applying the Linux Maintenance Release 93Procedure StepsStep Action1Load the CD containing the MCP Core Linux platformMaintenance Release into the CD-

Pagina 119

94 Maintenance ReleasesAttention: This is a major package upgrade. It upgrades thekernel as well as many other base level packages. Stop allMCP compon

Pagina 120 - • Fault-Performance Managers

Applying the Oracle Maintenance Release 9522Reboot the server:rebootAttention: If you are applying a platform patch to a server withonly the platform

Pagina 121 - Common procedures

96 Maintenance ReleasesAttention: The time it takes to patch the Oracle Database varies frompatch to patch. It can take anywhere from a few minutes up

Pagina 122 - 122 Common procedures

Installing the online Help files 97ERROR at line 1: ORA-00955: name is already used by anexisting object•DROP PACKAGE sys.dbms_apply_user_agent*ERROR

Pagina 123

98 Maintenance Releases6Change directory:cd /var/mcp/run/MCP_11.0/<prov>_0/bin7Transfer the file to the Provisioning Manager server using thesft

Pagina 124

Firmware upgrades 99Firmware updates navigation• "Determining the current firmware version" (page 99)• "Comparing the firmware versions