202 Install and configure IP Trunk 3.01 (and later) node
Figure 39
NTND26 cable routing diagram
5 Connect the DCH (P5) connector of the NTCW84KA to the outward
side of the 15-pin I/O panel filter connector.
—End—
Install filter and NTND26 cable (for MSDL and DCHIP cards in
different Large System equipment rows)
Follow the steps in Procedure 12 "Installing the filter and NTND26 cable
for MSDL and DCHIP cards in different Large System equipment " (page
202) to install the filter and NTND26 cable for MSDL and DCHIP cards in
different Large System equipment rows.
Procedure 12
Installing the filter and NTND26 cable for MSDL and DCHIP cards in different
Large System equipment rows
Step Action
1
Install the bracket for the 15-pin I/O panel filter connector in the J16,
J17, J37 or J38 I/O panel opening of the I/O panel of the Network
Module or Core/Net Module that contains the MSDL card.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright © 2007, Nortel Networks
.