42 System architecture
four segments per superloop requires one superloop network card and
one controller-2 card
eight segments per superloop requires one superloop network card
and two controller-2 cards
one segment per superloop/three segments on a second superloop
requires two superloop network cards and one controller-2 card
two segments per superloop/six segments on a second superloop
requires two superloop network cards and two controller-2 cards
As an example of a superloop configuration, Figure 16 "Eight segments
per superloop" (page 43) shows eight segments per superloop. If a
segment in this configuration is equipped with analog line cards and trunk
cards, a high concentration environment of 120 timeslots to 128–512
Terminal Numbers (TNs) is provided. If half of the data TNs on digital
line cards are enabled, this configuration provides a concentration of 120
timeslots to 768 TNs.
For a detailed description of superloop-to-segment configurations, see
Communication Server 1000M and Meridian 1 Large System Planning and
Engineering (NN43021-220),.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Large System Overview
NN43021-110 02.05 Standard
30 September 2008
Copyright © 2003-2008 Nortel Networks
.