MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide
129
Copyright © 2006 Nortel Networks
3 Use the values from the table that follows to complete the Web
Client Manager tab parameters.
The shaded rows indicate values that must be addressed by the
installer.
Application Server
Port
5060 default
Click-to-call
Cancel Delay
18 default
Table 25 User Agent Server tab (Continued)
Parameter Recommended value Notes Example
Table 26 Web Client Manager tab (Sheet 1 of 2)
Parameter
Recommended
value Notes Example
WCM Socket Server Active checked checked
WCM Socket Server Host <machine logical IP
address of the Web
Client Manager>
120.120.12.43
WCM Socket Server Port 3090 default
Audio RTP Port Low 50000 default
Audio RTP Port High 50100 default
Use SSL checked default
Keep Alive Ping checked default
Ping Time Out Timer 60 default
Ping Interval Timer 120 default
Connection Time Out Timer 360 default