194 Syslog Messages
Alarm Severity Syslog Level
MAJOR CRITICAL
MINOR ERROR
WARNING WARNING
* ERROR
Alarms are formatted according to the following pattern:
Id: <alarm sequence number>
Severity: <severity>
Name: <name of alarm>
Time. <date and time of the alarm>
Sender: <sender, e.g. system or the VPN Gateway ’s IP address>
Cause: <cause of the alarm>
Extra: <additional information about the alarm>
To simplify finding the desired alarm messages, this section lists alarms
with the name parameter on top.
Name: isd_down
Sender: <IP>
Cause: down
Extra:
Severity: critical
A member of the NVG cluster is down. This alarm is only sent if the
cluster contains more than one VPN Gateway.
Name: single_master
Sender: system
Cause: down
Extra:
Severity: warning
Only one master VPN Gateway in the cluster is up and running.
Name: log_open_failed
Sender: <IP>, event
Cause and Extra are explanations of the fault.
Severity: major
The event log (where all events and alarms are stored) could not be
opened.
Name: make_software_release_permanent_failed
Sender: <IP>
Cause: file_error | not_installed
Extra: "Detailed info"
Severity: critical
Failed to make a new software release permanent after being
activated. The system will automatically revert to the previous version.