Chapter 4 Installing option cards and DIMMs 71
Nortel VPN Router Installation — VPN Router 2700
4 Attach the antistatic wrist strap that was shipped with the VPN Router 2700
(see Attaching the antistatic wrist strap” on page 64).
5 To replace a DIMM, remove the installed DIMM as follows:
a Press down the locking lever on either side of the DIMM (Figure 26 on
page 72).
b Pull the DIMM up to remove it from the slot.
6 Press down the locking lever on either side of the slot where you plan to
install the new DIMM (Figure 26 on page 72).
7 Place the new or replacement DIMM in the slot (Figure 26 on page 72).
Use the alignment keys to properly position the DIMM in the slot.
8 Press the DIMM firmly into the socket.
9 Pull up the locking lever on either side of the DIMM to snap it into position.
Caution: Risk of equipment damage
Electrostatic discharge can damage VPN Router 2700 components.