102 Option settings
Address
Switch SW15 or SW16 and logic on the card always address the four
UARTs using a pair of addresses: 0 and 1, 2 and 3 through 14 and 15. The
configurations for both switches are shown in Table 42 "QSDI paddle board
address switch settings" (page 102). To avoid system problems, switches
SW15 and SW16 must not be configured identically.
Table 42
QSDI paddle board address switch settings
SW15
Port 1 Port 2
Switch settings
SW16
Port 3 Port 4 1* 2
+
34
5
6
7
8
01
E X off off off off off off
23
E X off off off off off
on
4
5
E X off off off off
on
off
6
7
E X off off off off
on on
89
E X off off off
on
off off
10 11
E X off off off
on
off
on
12 13
E X off off off
on on
off
Device
pair
addresses
14 15
E X off off off
on on on
* To enable ports 1 and 2, set SW15 position 1 to ON. To enable ports 3 and 4, set SW16 position 1
to ON.
+
For each X, the setting for this switch makes no difference, because it is not used.
DTE/DCE mode
Each serial port can be configured to connect to a terminal (DTE equipment)
or a modem (DCE equipment). Instructions for configuring the DTE/DCE
switches SW2, SW3, SW4, SW5, SW6, SW7, SW8, and SW9 are shown in
Table 43 "QSDI paddle board DTE/DCE mode switch settings" (page 103).
Example: Port 1 is changed from DTE to DCE by reversing every switch
position on SW3 and SW2; that is, switches that were off for DTE are turned
on for DCE, and switches that were on for DTE are turned off for DCE.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.