Nortel-networks Circuit Card 311 Manual de usuario Pagina 75

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 113
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 74
Multifrequency sender cards 75
Line cards
Procedure 5
Testing line cards
Step Action
Use this procedure to test a line card.
1
Log into the system:
LOGI (password)
2
Perform a network memory test, continuity test, and signaling test on
a specific loop and shelf:
LD 30
SHLF l sloop and shelf numbers
If the system response is other than OK, see Software Input/Output
Reference Administration (NN43001-611) to analyze the
messages.
3
For a line card on a super loop, perform a signaling test on a specific
card or unit:
UNTT l s c loop, shelf, and card numbers
For the NT8D02 Digital Line card, enter:
UNTT l s c u loop, shelf, card, and unit numbers
If the system response is other than OK, see Software Input/Output
Reference Administration (NN43001-611) to analyze the
messages.
4
End the session in LD 30:
****
—End—
Multifrequency sender cards
Procedure 6
Testing multifrequency sender cards
Step Action
Use this procedure to test a multifrequency sender (MFS) card or the MFS
function of an NT8D17 Conference/TDS card.
1
Log into the system:
LOGI (password)
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.
Vista de pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 112 113

Comentarios a estos manuales

Sin comentarios