
80 Acceptance tests
If the system response is other than OK, see Software Input/Output
Reference — Administration (NN43001-611) to analyze the
messages.
5
End the session in LD 34:
****
6
Using a maintenance telephone, log into the system.
See "Communicating with the Meridian 1" in the Software
Input/Output Reference — Administration (NN43001-611) for details
on accessing the system using a maintenance telephone.
7 From the maintenance telephone, enter:
LD#34##
To test outpulsers and channels for the TDS loop, see Table 12 "TDS
tone tests" (page 80) for a sample of the input commands used with
the maintenance telephone. See Software Input/Output Reference
— Administration (NN43001-611) for all tones that can be tested.
8 Exit LD 34 from the maintenance telephone:
****
—End—
Table 12
TDS tone tests
Input command
Dial pad
equivalent Description
BSY#loop## 279#loop## Provides busy tone from TDS loop specified.
C##
2##
Removes any active tone.
DIA#loop## 342#loop## Provides dial tone from TDS loop specified.
OVF#loop## 683#loop## Provides overflow tone from TDS loop specified.
RBK#loop## 725#loop## Provides ringback tone from TDS loop specified.
RNG#loop## 764#loop## Provides ring tone from TDS loop specified.
**** Exits TDS test program.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.
Comentarios a estos manuales