Installing the server and connecting the peripheral devices Standard 1.01
58 CallPilot
3 At the switch, connect the ELAN network cable to an MAU (Ethernet)
transceiver. Then complete the connection from the transceiver to the
switch.
What’s next?
.
DANGER
Risk of fire hazard
The NTRH9069 MAU is not suitable for installation in ducts,
plenums, or other spaces used for environmental air. Do
not install it above a false ceiling or below a raised floor,
unless it can be confirmed that these spaces are not used
to convey environmental air.
IF the server will THEN
be connected to a CLAN continue with page 59.
not be connected to a CLAN continue with installing the software
feature key adapter (dongle). See page
60.