Chapter 23 Replacing or upgrading a power supply 279
BCM200/400 4.0 Installation and Maintenance Guide
3 Secure the power supply to the main unit. Align the power supply mounting holes with the
holes in the main unit. Install the screws at the rear of the main unit (see Figure 137). Do not
over-tighten the power supply mounting screws.
Figure 137 Install the BCM200 power supply chassis screws
4 Run the P4, P5, or P6 power supply cable and the IDE cable to the hard disk. The I/O card is
not installed in the main unit for this step:
a Route the power cable between the I/O card chassis standoffs in the area shown (see
Figure 138). Run the IDE cable in the same manner.
b Tie-wrap the power cable to the hard disk cable. Position the tie-wrap 1/2 inch from the
hard disk cable sheathing.
c Ensure the remainder of the power cable does not interfere with internal components.
Note: Install the power supply carefully. Ensure the power supply cables are not
entangled or crushed against any internal components.