Nortel Networks CVX 600 Manual de usuario Pagina 97

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 168
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 96
Checking the LEDs
296-1011-202 Rel. 5.0, Doc. Rev. 02.01 2-53
Chassis Connections
LEDs on DAC-SM
The following table describes the LEDs on the DS1-DAC-SM, E1-DAC-SM, and
DS3-DAC-SM:
LED State Meaning
Pwr Off
On (green)
Power off
Power on
Good On (green)
Off
Successful system boot: no errors detected
No power: failure detected or on standby
Fail Off
On (red)
No power
Failure detected
Redun Off
On (green)
No power or redundancy
A working redundant configuration
YEL (1, 1 to 2,
1 to 12 or
1 to 24)
On (yellow)
Off
Yellow alarm: remote switch is not receiving
a signal from the CVX 600
No alarm
RED (1, 1 to 2,
1 to 12, or
1 to 24)
On (red)
Off
Red alarm: remote switch is not receiving a
signal from the remote switch
No alarm
Vista de pagina 96
1 2 ... 92 93 94 95 96 97 98 99 100 101 102 ... 167 168

Comentarios a estos manuales

Sin comentarios