134 NT5D97 Dual-port DTI2/PRI2 installation and removal
NT5D97AD DIP switch settings
The NT5D97 DDP2 card is equipped with 6x2 sets of DIP switches for
trunk parameters settings for port 0 and port 1 respectively. Additionally,
the DDP2 card is equipped with one set of four DIP switches for the Ring
Ground setting. The NT5D97AA/AB has one set of eight DIP switches and
NT5D97AD has two sets of ten DIP switches for the D-channel Handler
parameters setting.
The DIP switches are used for the setting of default values of certain
parameters. Firmware reads the general purpose switches, which sets the
default values accordingly
Table 45
DIP switch settings for NT5D97AD
Card
Trunks
0 and 1
Port 0 Port 1 Trunk 0 Trunk 1
ENB/DSB mounted on the face
plate
S1
Ring Ground S16
DPNSS S8 S9
MSDL S9
TX Mode S2 S10
S3 S13
S4 S14LBO Setting
S5 S15
Receiver Interface S6 S11
General Purpose S12 S7
Refer to DIP switch locations in Figure 56 "Dip switches locations for
NT5D97AD" (page 135).