MCS 2-server Sun Fire V210 (RoHS) Solaris Installation and Commissioning Guide
117
Copyright © Nortel Networks Limited 2006
15 Use the table that follows to modify the fields for the Transport
Management tab.
The shaded rows indicate values that must be addressed by the
installer. Modify the public fields only. There are no private
addresses.
Call queue high threshold 70 70
Call queue low threshold 40 40
Other queue high threshold 40 default
Other queue low threshold 5 default
Database queue high threshold 40 40
Database queue low threshold 1 default
Protocols Monitored sip default
Table 15 Overload Controls tab (Continued)
Parameter
Recommended
value Notes Example
Table 16 Transport Management tab (Sheet 1 of 3)
Parameter Recommended value Notes Example
Service Name BBUA default
Server ID <specific to machine> App1 Server ID=1
App2 Server ID=2
Standalone Server checked
Server Parameter:
Label
Public_Static_Address default
Server Parameter:
Value:
<machine logical IP of
application server>
Enter the machine
logical IP of the
application server
you are working on.
120.120.
13.25
HeartBeat Port 40001 default
Sending Interval 250 default
HeartBeat Timeout 3 default