Nortel Networks Server 1005r Manual de usuario Pagina 119

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 206
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 118
June 2007 Replacing basic chassis components
1005r Server Maintenance and Diagnostics 119
Figure 23: Cooling fan assembly
6 Loosen the captive screw (B) that attaches the four-fan assembly to
the chassis.
7 Lift the fan module straight up and remove it from the chassis.
8 Lower the new fan module into place.
9 Tighten the captive screw (B).
10 Connect the fan cables to the correct fan connectors on the front
panel I/O board. The fan connectors are labeled on the front panel I/
O board.
11 Replace the processor air duct.
12 Replace the chassis cover.
13 Take the ESD strap off.
14 Connect the AC power cords, peripheral devices, and restart the
server.
Vista de pagina 118
1 2 ... 114 115 116 117 118 119 120 121 122 123 124 ... 205 206

Comentarios a estos manuales

Sin comentarios