RAID operations Standard 1.10
144 CallPilot
Result: The display changes to ONLIN A01-01.
11 Select A01-02 and press the Spacebar.
Note: The drives blink when you select them.
12 Press Enter to End the Array.
Result: The blinking stops.
13 Press F10 to configure the logical drive.
14 Press the spacebar to select Configuration Array.
Result: Span-1 appears in the box opened for the A01 logical drive.
15 Press F10 to configure the logical drive.
Result: The system prompts you for the logical drive to
consecutively select:
RAID 1;
Size: accept the size displayed
Accept
SPAN = NO
Change the last value to NOSPAN, if required.
16 Select Accept and press Enter twice to accept these new values.
Result: The system prompts you to save the configuration.
17 Select YES and press Enter.
18 Press ESC to exit the submenus.
19 In the Management menu, choose the Initialize submenu.
20 Press F2 to select the logical drive.
21 Press F10 and consecutively select YES to initialize the drive pack.
22 When the initialization is complete, press any key to return to the
Management menu.
23 Press ESC to exit the utility. Save the configuration when prompted.
24 Press Ctrl+Alt+Delete as indicated by the menu to reboot.