RAID operations Standard 1.10
142 CallPilot
Configuring RAID using LSI320-1
controller and Ctrl+M
The configuration of the RAID card is stored on both the card and the
hard drive. Typically you are not required to reconfigure RAID unless
you are making a change to the RAID system (for example, if you
replace the hard drives with higher capacity hard drives).
To configure an LSI320-1 RAID system
To configure RAID, do the following:
1 Turn on the server and press Ctrl+M when prompted during system
bootup.
Note: The Ctrl+M utility can take up to 1 minute to launch with 1L37
firmware. The system can appear frozen. Do not reset.
2 From the Management menu, select Objects and press Enter.
.
CAUTION
Risk of data loss
This procedure requires that the logical drive be initialized.
When you initialize the logical drive, all data on the hard drives
is erased.
Do not perform this procedure unless you are replacing the
hard drives or you are rebuilding the CallPilot system (that is,
reinstalling the Windows operating system and CallPilot
software).
WARNING
Nortel strongly recommends that you not perform low
level formatting. Performing low level formatting results
in the drives becoming unusable.