RAID operations Standard 1.10
140 CallPilot
If the firmware is not correct, perform a firmware update. For
instructions, see “To upgrade or downgrade the RAID firmware” on
page 140.
To upgrade or downgrade the RAID firmware
The firmware of the RAID card is upgraded through a flash process. The
flash process is initiated by running the RAID card firmware update
utility on the CallPilot DVD.
1 Insert the CallPilot Image DVD for the platform into the DVD combo
drive.
2 Power down the CallPilot server.
3 Restart the CallPilot server.
Result: The server boots from the DVD and the Startup Menu
appears.
1.Install CallPilot server image for 1005r and
boot (recommended)
2.Install CallPilot server image for 1005r and
exit to DOS
3.Utilities (BIOS, Firmware, etc...)
4 Enter 3 to run Utilities (BIOS, Firmware, etc...) from the Startup.
Result: The Nortel CallPilot Image Menu appears.
1.1005r server BIOS update
ATTENTION
Perform this procedure only if the firmware version is
not the version identified in this section.
WARNING
Nortel strongly recommends that you not perform low
level formatting. Performing low level formatting results
in the drives becoming unusable.