Nortel Networks Server 1005r Manual de usuario Pagina 173

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 206
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 172
June 2007 Replacing or adding voice processing boards
1005r Server Maintenance and Diagnostics 173
18 Line up the two grooves on the back lip of the PCI riser assembly
with the pins on the rear panel as shown in the following illustration.
19 Hold the PCI riser assembly by the two blue handles (A) and push
the assembly into the server board. Refer to “PCI riser card
assembly” on page 169.
Figure 50: PCI riser assembly rear studs and slots
20 Reconnect the DS30X cable or cables to the MPB96 card or cards.
You must reconnect each cable to the same MPB96 card it was
previously connected to. Use the labels you applied as a guide.
21 Replace the chassis cover.
22 Take the ESD strap off.
23 Power up the server and log on to Windows.
ATTENTION
If the PCI riser assembly is not fully seated, the server can
malfunction.
Vista de pagina 172
1 2 ... 168 169 170 171 172 173 174 175 176 177 178 ... 205 206

Comentarios a estos manuales

Sin comentarios