Install NTCW84JA Large System I/O Panel 50-Pin filter adapter 195
block by releasing the latching pins on the filter block and pulling the
NT8D81AA cable away.
3
Unscrew the existing filter adapter from the I/O panel. There is one
screw on the lower front of the adapter and one screw on the upper
back of the adapter. Remove the adapter.
4
Re-position the new NTCW84JA filter adapter in the now vacant I/O
panel opening. (See Figure 35 "NTCW84JA 50 pin I/O Panel Filter
Connector Block" (page 195).)
5
Attach the new NTCW84JA to the I/O panel by securely fastening
the top back screw and the bottom front screw.
6
Reconnect the NT8D81AA cable and secure it in place by snapping
shut the locking latches provided on the NTCW84JA connector.
—End—
Figure 35
NTCW84JA 50 pin I/O Panel Filter Connector Block
Even though the ITG-Pentium 24-port trunk card is a two-slot card, only
the leftmost slot is counted for the card slot number. Example: for an
ITG-Pentium 24-port trunk card installed in slots 2 and 3, the slot number
is 2.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 01.01 Standard
Release 5.0 30 May 2007