212 Install and configure IP Trunk 3.01 (and later) node
3
Fit the DCHIP PC Card NTMF29BA cable assembly through the
faceplate slot and push it home into the header.
4
Fit the DCHIP PC Card connector of the NTMF29BA cable assembly
into Port 0 (the upper socket) on the DCHIP card.
5
Fit the clamp over the PC Card connector and into the bracket.
Ensure that the cable is fitted through the clamp, then secure it to
the bracket with the attached screw.
6
Make sure the eject button protrudes when the card is fully inserted.
Do not use excessive force when inserting the DCHIP PC Card.
—End—
DCHIP cable routing, Large Systems
NTMF29BA/NTND26AA cable routing
The NTND26AA cable from the MSDL forms a direct flying lead connection
to the NTMF29BA cable from the DCHIP card. The cables must be routed
internally to the system along the cabling channels, as shown in Figure 46
"Large System DCHIP cabling setup: intra-column/cube" (page 212). The
NTND26 cable is available in various lengths.
Figure 46
Large System DCHIP cabling setup: intra-column/cube
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 01.01 Standard
Release 5.0 30 May 2007
Copyright © 2007, Nortel Networks
.