TM 3.1 OA and M procedure summary 349
3
Click Start transmit. See Figure 140 "ITG Transmit Options window"
(page 349).
—End—
TM 3.1 transfers the data to the appropriate cards using FTP.
Figure 140
ITG Transmit Options window
The following comments apply to the ITG Transmit Options:
To transmit Node Properties (BOOTP.1), select the node in the top
window.
Node Properties (BOOTP.1) can be transmitted while the IP trunk cards
are enabled, but do not take effect until all the IP trunk cards in the
node are rebooted.
To transmit Card Properties (CONFIG1.INI), the entire node in the top
window or an individual card can be selected, but in either case it is
necessary to select to transmit to the entire node.
Card Properties (CONFIG1.INI) can only be transmitted to the IP trunk
cards when the cards are disabled.
For the Card Properties (CONFIG1.INI) to take effect, the IP trunk cards
must be re-enabled.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 01.01 Standard
Release 5.0 30 May 2007
Copyright © 2007, Nortel Networks
.