Page 154 of 906 Option settings
553-3001-211 Standard 3.00 August 2005
Device number SW15
Port 3 Port 4 1 2 3 4 5 6 7 8
0 1 off off off off off on on on
2 3 off off off off off on on off
4 5 off off off off off on off on
6 7 off off off off off on off off
8 9 off off off off off off on on
10 11 off off off off off off on off
12 13 off off off off off off off on
14 15 off off off off off off off off
Note 1: On SW16, positions 1, 2, 3, and 4 must be OFF.
Note 2: To avoid address conflicts, SW14 and SW15 can never have identical setting.
Note 3: To disable ports 3 and 4, set SW15 position 1 to ON.
Table 61
QPC841 baud rate
Baud
rate
Port 1 SW10 Port 2 SW11 Port 3 SW12 Port 4 SW13
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
150 off off on on off off on on off off on on off off on on
300 off on off on off on off on off on off on off on off on
600 off off off on off off off on off off off on off off off on
1200 off on on off off on on off off on on off off on on off
2400 off off on off off off on off off off on off off off on off
4800 off on off off off on off off off on off off off on off off
9600 off off off off off off off off off off off off off off off off