Page 634 of 906 NT8D15 E&M Trunk card
553-3001-211 Standard 3.00 August 2005
Trunk circuit features
Trunk unit functions
The functions provided by each unit on the E&M trunk card include 2-wire
signaling, 4-wire signaling, and paging operation as follows:
• 2-wire, E&M Type I signaling (see Figure 144 on page 635) with:
— near-end seizure and outpulsing with M lead
— ground detection with E lead
— voice transmission through tip and ring for transmit and receive
• 4-wire, E&M Type I and II signaling (see Figure 145 on page 636),
2-way dial repeating with:
— echo suppression for Type I signaling
— switchable 7 dB and 16 dB pads for carrier interface
— voice transmission and reception through two separate paths
— Type I signaling through E&M leads
— Type II signaling with near-end seizure by SB/M leads and far-end
detection by E/SG lead
• 4-wire, DX signaling (see Figure 146 on page 637)
• paging trunk operation (see Figure 147 on page 638) with support access
by low-resistance path at the PG/A1 leads
Note: Paging end-to-end signaling is not supported.