Nortel-networks Circuit Card Manual de usuario Pagina 809

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 908
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 808
NTCK16 Generic Central Office Trunk cards Page 809 of 906
Circuit Card Description and Installation
Therefore the following steps must be followed when the Generic XFCOT is
installed:
1 Define Loss Switching mode. Respond to the prompts in LD 97 as shown.
2 Define Loss Switching Class Of Service. Respond to the prompts in LD 14
as shown.
LD 97 – Defining Loss Switching mode.
Prompt Response Description
REQ: CHG
TYPE: SYSP IPE system parameters configuration
...
NATP YES Select North American transmission plan.
Note: The default to the NATP prompt is NO, and
therefore this prompt must always be checked during
installation.
LD 14 – Defining Loss Switching Class Of Service.
Prompt Response Description
REQ: CHG
TYPE: COT
XTRK XCOT
SIGL LOP
...
CLS
LOL
LOL= Long Line
Note: The XFCOT uses the CLS Long Line (LOL) and
Short Line (SHL) for Loss Switching purposes and that
the card and trunk type is different from the XUT.
Vista de pagina 808