NT8D72 PRI2 27
Faceplate Destination Type Description
RCV MON Miniature bantam jack Monitor DSI from network
XMT MON Miniature bantam jack Monitor DSI from PRI
Cable requirements
Table 3 "NT8D72AB and NT8D72BA PRI: Cables and cable lengths" (page
27) lists the types of cable used and the lengths required for internal and
external NT8D72 PRI2 connections.
Note: No additional cabling is required for nB+D configurations. Multiple
PRIs and the D-Channel are associated at the PRI prompt in LD 17.
Table 3
NT8D72AB and NT8D72BA PRI: Cables and cable lengths
Cable Type From To
Maximum length
(meters)
NT8D79AA PRI card Clock controller (CC-0)
2.13
NT8D79AA PRI card Clock controller (CC-1)
2.13
QCAD328A PRI card DCH card
1.8
QCAD328B PRI card DCH card
5.5
QCAD328C PRI card DCH card
10.67
QCAD328D PRI card DCH card
15.24
NTND26AA PRI card MSDL
1.8
NTND26AB PRI card MSDL
5.5
NTND26AC PRI card MSDL
10.67
NTND26AD PRI card MSDL
15.24
NT8D85AB PRI card Network Network Card
15.24
RS-232 PRI card Echo canceller
15.24
NT8D7207 PRI card I/O panel
3.05
NT8D7205 I/O panel
crossconnect
15.24
Carrier interface
The NT8D72 PRI2 provides an interface to the 2Mb external digital
line either directly or through an office repeater, echo canceller or line
terminating unit (LTU).