280 2.0 Mb PRI implementation
Prompt Response Description
PERS
ttt
Persistence Timer for Group II problems.
Enter 0-256 msec in increments of 2 msec. Default is 50
(=100ms).
CLRS
ttt
Clearance Timer for Group II problems. Enter 0 - 256 msec in
increments of 2 msec. Default is 50 (=100ms).
OOSC
nnn
Out-of-Service Counter.
Range for nnn of 0-255 with a default of 5.
LD 73 - Changing trunk pad category values
Prompt Response Description
REQ CHG Change data.
TYPE PRI2 2.0 Mb PRI.
FEAT PADS
PDCA
#
PAD table-0 is default and is hard coded.
The following prompts define the pad levels.
The receiving pad code is r and the transmission pad code is t. These entries have the range 0-15.
The pad values (in decibels) relating to these codes are shown after this table.
ONP
rt
On-premises extension.
DSET
rt
Meridian Digital set.
Prompted only if the 2.0 Mb Gateway feature is equipped.
OPX
rt
Off-premises extension.
DTT
rt
Digital TIE trunks.
SDTT
rt
Digital Satellite TIE trunks.
NTC
rt
Nontransmission compensated.
TRC
rt
Transmission compensated.
DCO
rt
Digital COT, FEX, WAT, and DID trunks.
VNL
rt
Via Net Loss.
DTO
rt
2.0 Mb PRI2 digital TOLL office trunks.
ACO
rt
Analog CO or WATS trunks.
AFX
rt
Analog FEX trunks.
ADD
rt
Analog DID trunks.
SATT
rt
Analog satellite TIE trunks.
ATO
rt
Analog TOLL office trunks.
PRI2
rt
2.0 Mb PRI trunk.
Prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=2.0 Mb PRI.