Nortel-networks 1000M Manual de usuario Pagina 330

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 474
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 329
330 Connecting the telephones
WARNING
If connecting to a message waiting line card, unseat the
card from its assigned slot before continuing with the next
step.
3
Connect two NTAK9204 cables (one from connector J1 and one
from connector J2) from the protection module to the cross-connect
terminal.
Terminate the cables as shown in Figure 136 "NE-500/2500-type
telephone cross-connections" (page 326).
4
Cross-connect the J1 cable to the Tip and Ring connections coming
from the line card.
Refer to "Preprogrammed data" (page 373) for default DN
assignments.
5
Cross-connect the J2 cable to the off-premise telephone.
6 Install the regulatory label provided with the Off-Premise Protection
Module on the inside right-hand wall of the cabinet (near the Velcro
wriststrap fastener) or chassis.
7
Install the line card in its assigned position.
Now, you can activate the telephone, as described in "Activating
telephones" (page 336).
—End—
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310 01.04 Standard
Release 5.0 13 May 2008
Copyright © 2008, Nortel Networks
.
Vista de pagina 329
1 2 ... 325 326 327 328 329 330 331 332 333 334 335 ... 473 474

Comentarios a estos manuales

Sin comentarios