330 Connecting the telephones
WARNING
If connecting to a message waiting line card, unseat the
card from its assigned slot before continuing with the next
step.
3
Connect two NTAK9204 cables (one from connector J1 and one
from connector J2) from the protection module to the cross-connect
terminal.
Terminate the cables as shown in Figure 136 "NE-500/2500-type
telephone cross-connections" (page 326).
4
Cross-connect the J1 cable to the Tip and Ring connections coming
from the line card.
Refer to "Preprogrammed data" (page 373) for default DN
assignments.
5
Cross-connect the J2 cable to the off-premise telephone.
6 Install the regulatory label provided with the Off-Premise Protection
Module on the inside right-hand wall of the cabinet (near the Velcro
wriststrap fastener) or chassis.
7
Install the line card in its assigned position.
Now, you can activate the telephone, as described in "Activating
telephones" (page 336).
—End—