54 Chassis system equipment
Differences between the Chassis system and the Cabinet system
Refer to Table 14 "Comparison of Chassis and Cabinet systems " (page
54) for a comparison of the Chassis system and the Cabinet system.
Table 14
Comparison of Chassis and Cabinet systems
Item
Chassis system Cabinet system
Physical packagin
g
Chassis NTDK91
Chassis expander NTDK92
Main Cabinet NTAK11
Two copper cables connect the
chassis to the chassis expander.
Fiber-optic cable connects the main
cabinet to the expansion cabinet
(upgraded systems may still have
copper cable connection).
Capacity
Chassis:
•
4 physical slots
•
logical slots (slots 1–6)
Chassis expander:
•
4 physical slots
(slots 7–10)
A
dd another item, "Expansion chassis"
-- additional NTDK91 chassis can be
connected with fiber-optic cable?
Main cabinet:
•
10 physical slots (slots 1–10)
Expansion cabinet:
•
Up to 4 additional NTAK11
cabinets can be connected with
fiber-optic cable (slots 20–50)
Supports up to 144 700 lines Supports up to 700 lines
Chassis installatio
n
Four Three chassis installation options:
• rack/equipment cabinet
•
vertically on a wall
•
horizontally on a wall
Two cabinet installation options:
• wall
•
floor
Cooling Forced air, thermally controlled cooling
(Fan installed inside chassis)
Convection cooling
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310 01.04 Standard
Release 5.0 13 May 2008