Vista de pagina 34
Cables and wires 35
Cable and wire
Purpose and description
NTAK19 cable SDI cable used with the NTAK02 circuit card
(see Note 1).
NTAK1118/1118 9- to 25-pin RS232 converter
cable
Connects SDI ports and terminals (see Note 1).
A0378652 F-F DCE to DTE converter, or
A0381016 F-M DCE to DTE converter
Connects SDI ports to equipment, such as TTYs
and modems.
NTBK04 1.5 Mbit DTI/PRI carrier cable
(A0394216)
Connects the NTAK09 1.5 Mbit DTI/PRI card to
the Channel Service Unit (CSU). The NTBK04
carries Tx and Rx pairs to a standard 5-pin
connector.
NTBK05AA/DA 2.0 Mbit DTI/PRI carrier cable
A0394217
Carries Tx and Rx pairs to a standard 120-Ohm
D-connector (see Note 1).
NT8D7205 DTI/PRI carrier cable
NTBK05CA coaxial cable
NTBK05DA twisted pair cable
NTAK10 2.0 Mbit DTI cable
NTAK79 2.0 Mbit PRI cable
NTAK50 2.0 Mbit PRI cable
These cables provide DTI/PRI connections. The
cables carry Tx and Rx pairs to a standard 5-pin
connector (see Note 2).
25-pair inside wiring cables equipped with
amphenol-type connectors
Extend the Intelligent Peripheral Equipment
connections from the system chassis to the
cross-connect terminal, and connect PFTUs.
#6 AWG (#40 Metric Wire Gauge) insulated
ground wire
Connects a system cabinet to a building ground
source.
#6 AWG (10 mm
2
) insulated ground wire (UK) Connects a system cabinet to a building ground
source.
#6 AWG (20 mm
2
) insulated ground wire
(Europe)
Connects a cabinet to a building ground source.
#8 AWG (10 mm
2
) insulated ground wire
(Germany)
Connects a cabinet to a building ground source.
Cross-connect wire Makes cross connections at the cross-connect
terminal.
Note 1: This cable is available in different versions, depending on local EMC specifications.
Note 2: These cables are not supported under EMC specifications VL43.140P.
Table 5 "AC power cord kits" (page 36) lists the AC power cord kits for
various countries. These cords connect a system cabinet to a commercial
AC power source.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310 01.04 Standard
Release 5.0 13 May 2008
Copyright © 2008, Nortel Networks
.
Vista de pagina 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 473 474

Comentarios a estos manuales

Sin comentarios