
NN10287-301 MCS 5100 3.5 Standard 5.0 December 2006
50
Copyright © 2006 Nortel Networks
Enter the <machine logical IP of the management
server>[Enter]
Example : 192.168.14.11
4 You will see the following message: "Enter the machine
logical IP address of the accounting server."
Enter the <machine logical IP of the accounting
server>[Enter]
Example : 192.168.14.11
You will see the following message: You have chosen to
configure NTP as follows:
Type of server: Application
NTP SOURCE (Management IP address): 192.168.14.11
Type of server: Application
NTP SOURCE (Accounting IP address): 192.168.14.11
Is the above configuration correct (y/n):
Select Y to continue or N to change.
5 Press Enter to continue.
6 You will see the following statement:
”You are now configuring IPMP (Multipathing)"
”Please have the Database Server Physical IP
addresses and the Machine Logical IP address
ready. Have 6 IP addresses that can be used as
ping buddies."
7 Press the Enter key to continue.
8 When you see the IP multipathing configuration for Sun Solaris
information appear, press Enter to accept it or type in a preferred
setting. The default failover timeout is set to 1000mSec.
9 Enter the primary machine physical IP address for the dmfe0
interface: <Physical IP address of the dmfe0
interface of the Database Server> [Enter]
Example: 192.168.14.12
10 Enter the secondary machine physical IP address for the dmfe1
interface:
<Physical IP address of the dmfe1 interface of
the Database Server> [Enter]
Example: 192.168.14.13
Comentarios a estos manuales