Chapter 4 Managing the Passport 8672ATME Module with Device Manager 71
Using the Passport 8672ATME Module
Figure 25 ATM PVC dialog box—ATM PVC tab
2 Highlight a PVC.
3 Click F5 Loopback.
The F5 Loopback dialog box opens with the F5 Loopback tab displayed
(Figure 26).
Figure 26 F5 Loopback dialog box
Table 13 describes the F5 Loopback tab fields.
Table 13 F5 Loopback tab field descriptions
Field Description
LbMgmtEnable Click to enable or disable the F5-OAM Loopback feature.
LbSendFrequency Enter the number of seconds (1-255) between transmitting OAM
loopback requests. The default value is 5 seconds.
LbRetryFrequency Enter the number of seconds (1-255) between attempting to
resend the transmission. The default value is 1 second.