72 Chapter 4 Managing the Passport 8672ATME Module with Device Manager
209195-B
Displaying F5 Loopback statistics
To display F5 Loopback statistics:
1 From the Device Manager menu bar choose Edit > ATM.
The ATM dialog box opens with the ATM PVC tab displayed (Figure 18).
2 Highlight a PVC.
3 Click F5 Loopback.
The F5 Loopback dialog box opens with the F5 Loopback tab displayed
(Figure 26).
4 Click the F5 Loopback Stats tab.
The F5 Loopback Stats tab is displayed (Figure 27).
Figure 27 F5 Loopback Stats tab
LbUpCount Enter the number of consecutive end-to-end F5-OAM loopback
cell responses (1-255) that must be received in order to change a
PVC connection state to up. The default value is 3 responses.
LbDownCount Enter the number of consecutive end-to-end F5-OAM loopback
cell responses (1-255) to be not received in order to change a
PVC state to down. The default value is 5 responses (not
received).
TrapEnable Click to enable or disable OAM traps. When enabled, a trap is
sent to the management station when rc2kAtmPvcOamVcStatus
is going up or down.
Table 13 F5 Loopback tab field descriptions (continued)
Field Description