Common Tops log messages (0201) DNC Logs 17
TOPS VSN Log and alarm messages
0002/001A
Message:
[Sending_PRU_name] was trying to communicate with [Receiving_
PRU_name] but could not. The entry definition in [Sending_PRU_name] was
not found, OR push/pull was invoked when not in entry. User action is
required.
Description:
The sending PRU could not communicate with the receiving
PRU because the software version in each were not the same.
Action:
The user must reinstall both PRUs from the load tape. If the problem
persists, then contact NT.
0002/001B
Message:
[Sending_PRU_name] was trying to communicate with [Receiving_
PRU_name] but could not. The result was a communication failure.
Description:
The sending PRU can not communicate with the receiving PRU
because the receiving PRU is not there. It is the responsibility of the sending
PRU to recover from the error or to declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, document the problem, restart both sending and receiving
PRUs, and then contact NT.
0002/001C
Message:
[Sending_PRU_name] was trying to communicate with [Receiving_
PRU_name] but could not. The result was that the location address of the
receiver was invalid.
Description:
The sending PRU could not communicate with the receiving
PRU. It is the responsibility of the sending PRU to recover from the error by
resending the message or to declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, then document the problem, and restart both sending and
receiving PRUs. If necessary, restart the SRUs in which both PRUs reside.
Record all action taken, and then contact NT.
0002/001D
Message:
[Sending_PRU_name] was trying to communicate with [Receiving_
PRU_name] but could not. The result was an interval timer error.
Description:
The sending PRU could not communicate with the receiving
PRU. It is the responsibility of the sending PRU to recover from the error by
resending the message or to declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, then document the problem, and restart both sending and
receiving PRUs. If necessary, restart the SRUs in which both PRUs reside.
Record all action taken, and then contact NT.
0002/001E
Message:
[Sending_PRU_name] was trying to communicate with [Receiving_
PRU_name] but could not. The problem is the sender [Sending_PRU_name]
could not obtain control blocks. User action is required.
Description:
The sending PRU could not communicate with the receiving
PRU. It is the responsibility of the sending PRU to recover from the error by
resending the message or to declare itself faulty.