Common Tops log messages (020A) DNC Logs 43
TOPS VSN Log and alarm messages
0001/0021
Message:
[PRU_name] was attempting to perform an SDM "Set Atomic
Commit" and failed. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two
80 character lines of optional data.]
Description:
The PRU tries to set the atomic commit for a Service Data
Manager operation and fails. Class error codes are: 1) run error, 2) task error,
and 3) IO error.
Action:
This log should never occur. If it does, contact NT immediately.
0001/0022
Message:
[PRU_name] was attempting to perform an SDM "Add table
TransID" and failed. table Name = [SDM_table] Access Mode = [read only/read-
write]. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two 80 character
lines of optional data.]
Description:
When the PRU tries to add a table to the Service Data Manager,
it fails. Class error codes are: 1) run error, 2) task error, and 3) IO error. The
error may be caused by a full internal array or a duplication in table names.
Action:
Record all information for NT.
0001/0023
Message:
[PRU_name] was attempting to perform an SDM "Set TNUM
TransID" and failed. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two
80 character lines of optional data.]
Description:
The PRU tries to set TNUM transID for a Service Data Manager
operation and fails. Class error codes are: 1) run error, 2) task error, and 3) IO
error.
Action:
This log should never occur. If it does, contact NT immediately.
0001/0024
Message:
[PRU_name] was attempting to perform an SDM "Get TNUM
TransID" and failed. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two
80 character lines of optional data.]
Description:
The PRU tries to get a TNUM transID for a Service Data Manager
operation and fails. Class error codes are: 1) run error, 2) task error, and 3) IO
error.
Action:
This log should never occur. If it does, contact NT immediately.
0001/0025
Message:
[PRU_name] was attempting to perform an SDM "Init TransID" and
failed. table Name = [SDM_table] Access Mode = [read only/read-write]. Error
Type = [Helix_IO_result], Error Class = [1,2,3]. [Two 80 character lines of
optional data.]
Description:
The PRU tries to initialize transID for a Service Data Manager
operation and fails. Class error codes are: 1) run error, 2) task error, and 3) IO
error.
Action:
This log should never occur. If it does, contact NT immediately.
0001/0026
Message:
[PRU_name] was attempting to perform an SDM "Start Transaction"
and failed. Error Type = [Helix_IO_result], Error Class = [1,2,3]. [Two 80
character lines of optional data.]