Application Call Processing Engine Log Messages (9442) 61
TOPS VSN Log and alarm messages
0003/0001
Message:
ACPE error. Unable to initialize; duplicate datafill detected during
executor initialization: [duplicate_data_string] reading SDM table:
[table_name].
Description:
This log is generated if a duplicate string is detected by the
ACPE when reading an SDM table. This means there is ambiguous reference
in the datafill. The ACPE can not go into a working state.
Action:
Change the datafill for one of the entries. (The location of the
duplicate data is given. The first occurrence of the data string is not specified.)
0003/0002
Message:
ACPE error. Unable to initialize; unresolved reference:
[offending_reference] in SDM table: [table_name].
Description:
This log is generated when datafill in the specified table
references a symbol that cannot be found. The ACPE cannot go into a working
state.
Action:
The unresolved reference must be corrected. (The locations in
which the search took place are unspecified.)
0003/0003
Message:
ACPE error. Unable to initialize SDM table: [table name] is too
large. Maximum size is [number_of_entries].
Description:
This log is generated when the number of entries in a table
exceeds the maximum. The existing data structure is unable to hold all the data.
Action:
Reduce the size of the table. The maximum table size is hard coded
and cannot be changed.
0003/0004
Message:
ACPE detected Voice Interface error. [Error_type_detected].
Source of error was Voice Interface SRU located at cabinet [number], slot
[number], channel [number]. VI error code: [decimal], Executor Involved:
[executor_name].
Description:
This log is generated when the Voice Interface (VI) returns an
error condition that is not caused by user interaction. The call is usually aborted.
The [error_type_detected] gives a brief description of the error.
Action:
No action. If the problem persists, it may be necessary to change the
specified voice channel or the whole SRU.
0003/0005
Message:
ACPE error. A parameter error was detected by the executor
[executor_name]. Debugging Information: [parameter/value].
Description:
This log is generated when an executor detects an error in an
input parameter.
Action:
Contact NT
0003/0006
Message:
ACPE error. An attempt was made to concatenate two different
coding methods. The prompts were: [segment_file_1] and [segment_file_2].
Debugging Information: [parameter/value].
Description:
This log is generated when a MPLPC-coded prompt is
concatenated with a prompt coded in PCM.
Action:
Record all information and report the problem to NT.
0003/0008
Message:
ACPE error. An attempt has been made to allocate more
[procedure_variable_type] procedures than the associated data structure can
hold. This indicates that there was an error while creating the ACPE. The
maximum number of provars permitted in the structure is [number].