Vista de pagina 26
Common Tops log messages (0202) DNC Logs 21
TOPS VSN Log and alarm messages
0003/002A
Message:
[PRU_name] received an IO error on path [file/directory_path
name]. The error was the result of trying to save the file to disk, but the file was
not opened for "writable" access.
Description:
The PRU encountered an error during an IO operation such as,
open, read, or write, on the file or directory. The operation was not performed
because it did not make its way to the server. The error is in the SRU where the
PRU resides. It is the responsibility of the PRU performing the operation to
recover from the error and to retry the operation. If it is unable to do so, then it
can declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, then reboot the PRU. If the problem persists, then reboot
the server which handles the IO operation. If neither reboot operations are
successful, then reboot the whole system. Document the problem, the
corrective action taken, and then contact NT.
0003/002B
Message:
[PRU_name] received an IO error on path [file/directory_path
name]. The error was the result of performing an illegal seek operation.
Description:
The PRU encountered an error during an IO operation such as,
open, read or write, on the file or directory. The operation was not performed
because it did not make its way to the server. The error is in the SRU where the
PRU resides. It is the responsibility of the PRU performing the operation to
recover from the error and to retry the operation. If it is unable to do so, then it
can declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, then reboot the PRU. If the problem persists, then reboot
the server which handles the IO operation. If neither reboot operations are
successful, then reboot the whole system. Document the problem, record all
action taken, and then contact NT.
0003/002C
Message:
[PRU_name] received an IO error on path [file/directory_path
name]. The error was the result of performing an operation on a file set using a
bad identifier for the file set.
Description:
The PRU encountered an error during an IO operation on the
file or directory. The operation was not performed because it did not make its
way to the server. This error is in the SRU where the PRU resides. It is the
responsibility of the PRU performing the operation to recover from the error and
to retry the operation. If it is unable to do so, then it can declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, then reboot the PRU. If the problem persists, then reboot
the server which handles the IO operation. If neither reboot operations are
successful, then reboot the whole system. Document the problem, record all
action taken, and then contact NT.
0003/002D
Message:
[PRU_name] received an IO error on path [file/directory_path
name]. The error was the result of performing an I/O operation, but the server
that was referenced [first_component_of_pathname], was not found.
Vista de pagina 26