320 Attendant Overflow Position
3. LD 10 – Add/change an Attendant Overflow Position DN on an analog
(500/2500 type) telephone.
LD 15 - Assign/change an Attendant Overflow Position DN and queue threshold timing.
Prompt Response Description
REQ: CHG Change existing data.
TYPE: ATT_DATA Attendant console options.
CUST Customer number
0-99
Range for Large System and CS 1000E system.
0-31
Range for Small System and Media Gateway 1000B.
- AQTT 0-(30)-255 Attendant queue timing threshold (AQTT).
- AODN
xxx...x
DN where calls are to be overflowed when they have been in
queue the time specified for AQTT.
LD 11 - Add/change an AOP DN and AOP Busy key.
Prompt Response Description
REQ: CHG Change existing data.
TYPE:
a...a
Telephone type. Type ? for a list of possible responses.
TN
lscu
Terminal Number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
cu
Format for Small System and Media Gateway 1000B where
c = card and u = unit.
KEY
xx yyy...y
Attendant Overflow Position DN.
xx = key number.
yyy...y = DN.
KEY xx OVB Attendant Overflow Position Busy key.
LD 10 - Add/change an Attendant Overflow Position DN on an analog (500/2500 type) telephone.
Prompt Response Description
REQ: CHG Change existing data.
TYPE:
500
Telephone type.
TN
lscu
Terminal Number
Format for Large System and CS 1000E system, where l =
loop, s = shelf, c = card, u = unit.
cu
Format for Small System and Media Gateway 1000B where
c = card and u = unit.
DN
yyy...y
Attendant Overflow Position DN.
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106 01.04 Standard
Release 5.0 27 July 2007