Nortel-networks NN43001-106 Manual de usuario Pagina 500

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 576
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 499
500 B34 Dynamic Loss Switching
Typically, there are different vintages of firmware in the field:
hard-coded B34 firmware, which is hardcoded with country-specific
defaults, ignores B34 type 12 messages, and accepts (where applicable)
Short Line/Long Line configuration type 5 messages
flexible B34 firmware with country-specific defaults, which is firmware
that is coded with country-specific defaults, accepts (where applicable)
Short Line/Long Line configuration type 5 messages, and accepts B34
type 12 messages which override any accepted Short Line/Long Line
configuration type 5 messages
flexible B34 firmware with universal defaults, which is firmware that is
coded with a universal B34 loss value default, may or may not ignore
Short Line/Long Line configuration type 5 messages, and accepts B34
type 12 messages which override any accepted Short Line/Long Line
configuration type 5 messages
To obtain the full functionality of B34 Dynamic Loss Switching, only the two
flexible vintages of firmware can be used.
Every time a new connection is established, the following process is followed
to determine if and how to adjust the loss involved in the connection:
the port type of the originator and terminator is determined, based on
the configurations of the originator and terminator, respectively
this port type is used as a row index (originator) and column index
(terminator) into a connection matrix, to determine the following:
whether to switch the pad in or out for the originator receive direction
whether to switch the pad in or out for the originator transmit direction
whether to switch the pad in or out for the terminator receive direction
whether to switch the pad in or out for the terminator transmit
direction
a message conveying this information is then sent to the originator and
terminator, if they are affected port types.
The B34 Dynamic Loss Switching feature, configured on a system basis,
introduces flexibility in the loss values to be switched. Where previously
the loss values were hardcoded on the analog trunk cards, they are
now software-configurable on a per-system basis. The loss switching is
still controlled by a connection matrix defined for specific markets. This
matrix cannot be changed. The loss levels to be used are configured in a
base-level table and alternative-level table in LD 97. The base level table is
the same as the one implemented and used by the B34 Static Loss Plan
Downloading feature; the alternative level table is a parallel table configured
for the B34 Dynamic Loss Switching feature.
Nortel Communication Server 1000
Features and Services - Book 1 of 6 (A to B)
NN43001-106 01.04 Standard
Release 5.0 27 July 2007
Copyright © 2007, Nortel Networks
.
Vista de pagina 499