430 Automatic Number Identification on DTI
Calling number information signaling is done using the MF signaling method.
This enhancement supports the three basic signaling methods for ANI.
These are Bell, NT400, and NT500.
Feature interactions
There are no feature interactions associated with this feature.
Feature packaging
This enhancement is included in Automatic Number Identification (ANI)
package 12.
Feature implementation
LD 16 - Define Central Office or Toll Office port types.
Prompt Response Description
REQ NEW CHG Add, or change
TYPE RBD Route Data Block.
...
DTRK (NO) YES Digital trunk route.
DGTP DTI Digital trunk type.
PTYP (DCO) DTO CO or Toll Office port type (default DCO).
Feature operation
No specific operating procedures are required to use this feature.