564 Busy Tone Detection for Asia Pacific and CALA
Prompt Response Description
NEDC ETH Either end control.
FEDC ETH Either end control.
LD 14 - Configure Busy Tone Supervision for a new Central Office Trunk.
Prompt Response Description
REQ NEW Add new data.
TYPE COT Central Office trunk.
TN
lscu
Terminal Number
Format for Large System and CS 1000E system,
where l = loop, s = shelf, c = card, u = unit.
cu
Format for Small System and Media Gateway 1000B where
c = card and u = unit.
XTRK EXUT Type is IPE EXUT. This includes the DXUT. (This prompt is
required only for the first unit defined on each card.)
CUST
xx
Customer number, as defined in LD 15
RTMB Route number and Member Number
0-511 1-4000
Range for Large System and CS 1000E system.
0-127 1-4000
Range for Small System and Media Gateway 1000B.
SIGL LOP Loop start level 3 signaling.
TIMP (600)
900
Termination Impedance.
BIMP (3COM)
3CM2
600
900
Balance Impedance. In the case of AUTO_BIMP, this BIMP
value is used as a default value if an optimum AUTO_BIMP is
not found or if the AUTO_BIMP test is not complete.
AUTO_BIM
P
YES Automatic Balance Impedance is set according to transmission
line parameters.
NO = default for new trunks.
SUPN YES Answer and disconnect supervision required.
-STYP
PIP
BTS
PIP BTS
Supervision Type.
Polarity Insensitive Pack.
Busy Tone Supervision.
Both options.
BTDT (0)-7 Busy Tone Detection Table number configured in LD 97. (This
prompt is required only for the first unit defined on each card.)
CLS (DIP)
DTN
Dial Pulse.
Digitone.