Symposium and DMS/MSL-100 Switch Guide 109
April 2004 Troubleshooting
Phoneset does not display the skillset name
If the phoneset does not display the skillset name, ensure that the following
conditions have been met:
! The SCAI service version used to connect to the switch is SCAI17 or later.
! The customer has subscribed to the default tuple TPQC11$ in table
SCAISSRV.
! The tuple TPQC11$ under category TPQC is created with the parameter
DISPTEXT in the ROUTECALL function.
! The DN from which the call is being routed has been associated to the
SCAI session.
Agent Real-Time Display does not show Hold/UnHold activity
If the Agent Real-Time Display (RTD) does not show Hold/Unhold activity,
ensure that the following conditions have been met:
! The SCAI service version used to connect to the switch is SCAI17 or later.
! The DN that is putting the call on hold has the ECM option, with the sub-
options CALL-EVENTS and SCAICC set to Y.
! The DN should be associated to a SCAI session.
! The ICM session on which the DV_CALL_HELD_U message is to be sent
is subscribed to the tuple TPCC15$ and SCAICC09$.