Symposium and DMS/MSL-100 Switch Guide 33
April 2004 Getting started
! Install the network cable from the router to the Channel Service Unit (CSU)
or any other transport device.
! Install the client CSU.
! Configure the connection between the DMS CSU and the client CSU.
! Configure the connection between the DMS CSU and the client router and
firewall.
! Configure the connection between the client router and firewall, and the
client applications (for example, IVR system, Windows 2000 Server, and
Symposium Call Center Server).
! Configure the client-side router and firewall.
Installing and configuring the EIU
To install and configure the EIU, you must perform these tasks on the switch:
! Install the EIU on the switch.
! Confirm the EIU is present and lists all entries as displayed in table
LIUINV.
! Configure an IP address for the switch in table IPNETWRK.
! Configure IP addresses for the EIU in table IPHOST.
! Configure the EIU in table IPTHRON.
For more information, refer to the Ethernet Interface Unit User Guide
(NTP 297-8991-910) and the ICM Router Guide (NTP 297-2233-903).
Installing and configuring ICM
To install and configure ICM, you must ensure that the following tasks have
been performed on the switch:
! Install ICM on the EIU.
! Configure the office parameters in the following table:
OFCENG Allocates resources for switch activities.